RoHS WEEE COMPLIANT
Items |
39102 Type HCX - Extreme Temperature Jacket Liquid-Tight Flexible Metal Conduit (LFMC) |
39112 Type HCX - Extreme Temperature Jacket Liquid-Tight Flexible Metal Conduit (LFMC) |
39122 Type HCX - Extreme Temperature Jacket Liquid-Tight Flexible Metal Conduit (LFMC) |
39131 Type HCX - Extreme Temperature Jacket Liquid-Tight Flexible Metal Conduit (LFMC) |
39141 Type HCX - Extreme Temperature Jacket Liquid-Tight Flexible Metal Conduit (LFMC) |
|||||
Description |
N/A
Zero halogen, thermoplastic rubber jacket no bonding wire Conduit shall be Anaconda SEALTITE® Type HCX. Conduit shall provide a flexible liquid-tight raceway for wiring and shall be constructed of continuously interlocked hot dipped zinc galvanized steel core with sunlight resistant rubber outer jacket. Type HCX conduit shall be used for applications where agency approvals are not required. Conduit IP 67 rated when installed with approved end connectors. |
N/A
Zero halogen, thermoplastic rubber jacket no bonding wire Conduit shall be Anaconda SEALTITE® Type HCX. Conduit shall provide a flexible liquid-tight raceway for wiring and shall be constructed of continuously interlocked hot dipped zinc galvanized steel core with sunlight resistant rubber outer jacket. Type HCX conduit shall be used for applications where agency approvals are not required. Conduit IP 67 rated when installed with approved end connectors. X X X X X X X |
N/A
Zero halogen, thermoplastic rubber jacket no bonding wire Conduit shall be Anaconda SEALTITE® Type HCX. Conduit shall provide a flexible liquid-tight raceway for wiring and shall be constructed of continuously interlocked hot dipped zinc galvanized steel core with sunlight resistant rubber outer jacket. Type HCX conduit shall be used for applications where agency approvals are not required. Conduit IP 67 rated when installed with approved end connectors. |
N/A
Zero halogen, thermoplastic rubber jacket no bonding wire Conduit shall be Anaconda SEALTITE® Type HCX. Conduit shall provide a flexible liquid-tight raceway for wiring and shall be constructed of continuously interlocked hot dipped zinc galvanized steel core with sunlight resistant rubber outer jacket. Type HCX conduit shall be used for applications where agency approvals are not required. Conduit IP 67 rated when installed with approved end connectors. |
N/A
Zero halogen, thermoplastic rubber jacket no bonding wire Conduit shall be Anaconda SEALTITE® Type HCX. Conduit shall provide a flexible liquid-tight raceway for wiring and shall be constructed of continuously interlocked hot dipped zinc galvanized steel core with sunlight resistant rubber outer jacket. Type HCX conduit shall be used for applications where agency approvals are not required. Conduit IP 67 rated when installed with approved end connectors. |
|||||
Type | N/A HCX | |||||||||
Electrical Trade Size | N/A 3/8 in12 mm | N/A 1/2 in16 mm | N/A 3/4 in21 mm | N/A 1 in27 mm | N/A 1-1/4 in35 mm | |||||
Length | N/A 100 ft30.48 m | N/A 100 ft30.48 m | N/A 100 ft30.48 m | N/A 100 ft30.48 m | N/A 50 ft15.24 m | |||||
Packaging | N/A Standard Carton | |||||||||
Inside Diameter | N/A 0.485 to 0.505 in12.319 to 12.827 mm | N/A 0.620 to 0.640 in15.748 to 16.256 mm | N/A 0.815 to 0.835 in20.701 to 21.209 mm | N/A 1.030 to 1.055 in26.162 to 26.797 mm | N/A 1.370 to 1.395 in34.798 to 35.433 mm | |||||
Outside Diameter | N/A 0.690 to 0.710 in17.526 to 18.034 mm | N/A 0.820 to 0.840 in20.828 to 21.336 mm | N/A 1.030 to 1.050 in26.162 to 26.670 mm | N/A 1.290 to 1.315 in32.766 to 33.401 mm | N/A 1.635 to 1.660 in41.529 to 42.164 mm | |||||
Approx. Inside Bend Radius | N/A 2.0 in50.8 mm | N/A 2.5 in63.5 mm | N/A 3.0 in76.2 mm | N/A 4.0 in101.6 mm | N/A 4.5 in114.3 mm | |||||
Approx. Weight per 100 ft | N/A 21 lbs9.53 kg | N/A 25 lbs11.34 kg | N/A 39 lbs17.69 kg | N/A 51 lbs23.13 kg | N/A 66 lbs29.94 kg | |||||
Installation |
N/A
|
|||||||||
Color | N/A BLACK | |||||||||
Optional Colors | N/A | |||||||||
Note | N/A Sizes above 2" available on special order | |||||||||
Application |
N/A
Where Flexibility is Required in Extreme Temperature Environments Temperature Range: -76°F to +302°F (-60°C to +150°C) |
|||||||||
Industry Certifications |
N/A
RoHS WEEE |
|||||||||
Core Material | N/A Galvanized Steel | |||||||||
Ingress Protection (IP) Rating | N/A Ingress Protection (IP) 66/67 | |||||||||
Jacket Material | N/A Thermoplastic Elastomers (TPE) | |||||||||
Jacket Benefits | N/A Extreme Cold High Heat Liquid Tight Zero Halogen | |||||||||
|