Print Back

Construction

  • Constructed of continuously interlocked hot dipped zinc galvanized steel core for exceptional crush and corrosion resistance
  • Durable, sunlight resistant thermoplastic PVC jacket that resists heat, oil and chemical breakdown

Description

  • Flexible metal core liquid tight conduit
  • Designed for applications that need superior resistance to petroleum, synthetic oils and chemical degradation
  • Uses standard liquid tight connectors for easy installation

Specifications

  • Galvanized steel core with liquid tight PVC jacket
  • Color: Black or Gray
  • Temperature range: -9°F to +221°F (-23°C to +105°C)
  • UV (sunlight) resistant
  • Corrosion resistant
  • Extra oil resistant

Applications

  • Extreme resistance to oil
  • Petrochemical and steel industries
  • Applications where no approvals are required

Certification

RoHS WEEE COMPLIANT

Type OR - Special Oil Resistant Jacket Liquid-Tight Flexible Metal Conduit (LFMC)
Unit of Measure
Items Type OR - Special Oil Resistant Jacket Liquid-Tight Flexible Metal Conduit (LFMC)
36602
Type OR - Special Oil Resistant Jacket Liquid-Tight Flexible Metal Conduit (LFMC)
Type OR - Special Oil Resistant Jacket Liquid-Tight Flexible Metal Conduit (LFMC)
36612
Type OR - Special Oil Resistant Jacket Liquid-Tight Flexible Metal Conduit (LFMC)
Type OR - Special Oil Resistant Jacket Liquid-Tight Flexible Metal Conduit (LFMC)
36622
Type OR - Special Oil Resistant Jacket Liquid-Tight Flexible Metal Conduit (LFMC)
Type OR - Special Oil Resistant Jacket Liquid-Tight Flexible Metal Conduit (LFMC)
36631
Type OR - Special Oil Resistant Jacket Liquid-Tight Flexible Metal Conduit (LFMC)
Type OR - Special Oil Resistant Jacket Liquid-Tight Flexible Metal Conduit (LFMC)
36641
Type OR - Special Oil Resistant Jacket Liquid-Tight Flexible Metal Conduit (LFMC)
Description N/A Thermoplastic PVC jacket no bonding wire

Conduit shall be Anaconda SEALTITE® Type OR. Conduit shall provide a flexible liquid-tight raceway for wiring and shall be constructed of continuously interlocked hot dipped zinc galvanized steel core with sunlight resistant PVC outer jacket. Type OR conduit shall be used for applications where agency approvals are not required. Conduit IP 67 rated when installed with approved end connectors.
Type N/A OR
Electrical Trade Size N/A 3/8 in12 mm N/A 1/2 in16 mm N/A 3/4 in21 mm N/A 1 in27 mm N/A 1-1/4 in35 mm
Length N/A 100 ft30.48 m N/A 100 ft30.48 m N/A 100 ft30.48 m N/A 100 ft30.48 m N/A 50 ft15.24 m
Packaging N/A Small Cartons
Inside Diameter N/A 0.485 to 0.505 in12.319 to 12.827 mm N/A 0.620 to 0.640 in15.748 to 16.256 mm N/A 0.815 to 0.835 in20.701 to 21.209 mm N/A 1.030 to 1.055 in26.162 to 26.797 mm N/A 1.370 to 1.395 in34.798 to 35.433 mm
Outside Diameter N/A 0.690 to 0.710 in17.526 to 18.034 mm N/A 0.820 to 0.840 in20.828 to 21.336 mm N/A 1.030 to 1.050 in26.162 to 26.670 mm N/A 1.290 to 1.315 in32.766 to 33.401 mm N/A 1.635 to 1.660 in41.529 to 42.164 mm
Approx. Inside Bend Radius N/A 2.0 in50.8 mm N/A 2.5 in63.5 mm N/A 3.0 in76.2 mm N/A 4.0 in101.6 mm N/A 4.5 in114.3 mm
Approx. Weight per 100 ft N/A 21 lbs9.53 kg N/A 25 lbs11.34 kg N/A 39 lbs17.69 kg N/A 51 lbs23.13 kg N/A 66 lbs29.94 kg
Installation N/A
  • Conduit used with standard liquid-tight connector for easy installation. IP 67 Rated when installed with approved connectors.
  • Delivers superior wiring protection where agency approvals are not required.
  • Manufactured in a full range of trade sizes from 3/8" through 4".
  • Smooth appearing jacket for exposed applications.
  • Rated for temperature range of -9ºF to +221ºF (-23ºC to +105ºC).
  • Provides liquid-tight raceway for electrical conductors.
Color N/A BLACK
Optional Colors N/A Gray
Note N/A Sizes above 2" available on special order.
Type OR-H available as special with heavy plated steel core and integral bonding wire.
Application N/A Where Exposure to Cutting Oils Occur
Temperature Range: -9ºF to +221ºF (-23ºC to +105ºC)
Industry Certifications N/A RoHS WEEE
Core Material N/A Galvanized Steel
Ingress Protection (IP) Rating N/A Ingress Protection (IP) 66/67
Jacket Material N/A Polyvinyl Chloride (PVC)
Jacket Benefits N/A Liquid Tight Oil Resistant