Type NMUA - Non-conductive, Liquid Tight, Flexible, Non-Metallic Conduit (LFNC-B)
Sealtite® Non-Metallic Conduit
Construction
- A continuous coil of PVC is embedded in flexible PVC for smooth inner and outer walls
Description
- Durable, sunlight resistant and flame retardant thermoplastic PVC that resists heat, oil and chemical breakdown
- Flexible and crush resistant non-conductive conduit
- Non-metallic Type B liquid tight conduit
- Also available by special order in other colors (consult the factory)
- Uses special non-metallic connectors for easy installation
- Can also be used with a liquid tight connector
- Additional Put-ups available
SPECIFICATIONS
- Smooth Inner and Outer PVC Walls with a Co-Extruded Reinforcing PVC Coil
- Color: Gray
- Temperature range: -17°F to +176°F (-27°C to +80°C)
- UV (sunlight) resistant
- Oil resistant
- UL Approved
Applications
- Suitable for projects calling for LFNC-B conduit
- Designed for standard commercial and industrial applications
- Approved in US (per NEC) for direct burial and in concrete
- Frequently used to protect wiring and connections in HVAC applications
Compliant with NEC Articles
- 300.22 (D) Information Technology Equipment
- Suitable for Hazardous Locations per NEC Articles
- 501.10(B)(2) Class I Div. 2
- 502.10(A)(2) Class II Div. 1 & 2
- 503.10(A)(3) and (B) Class III Div. 1 & 2
- 356 Liquid tight Flexible Nonmetal Conduit (LFNC-B)
- 645.5 (E) (2) Under raised floors
Certifications
UL 1660 DXOQ.E211327 / CSA Approved #20817 / RoHS WEEE COMPLIANT
Meets requirements of NFPA 79 (2024 Edition) Section 13.5.4 LFNC
Recommended ANACONDA SEALTITE® Fittings
Type B NMUA Conduit Fittings - Nylon, UL Listed to comply with UL standards
Unit of Measure
Items |
/Asset/a1036.jpg 39702 Type NMUA - Nonconductive Conduit Liquid-Tight Flexible Non-Metallic Conduit (LFNC) |
/Asset/a1036.jpg 39712 Type NMUA - Nonconductive Conduit Liquid-Tight Flexible Non-Metallic Conduit (LFNC) |
/Asset/a1036.jpg 39722 Type NMUA - Nonconductive Conduit Liquid-Tight Flexible Non-Metallic Conduit (LFNC) |
/Asset/a1036.jpg 39731 Type NMUA - Nonconductive Conduit Liquid-Tight Flexible Non-Metallic Conduit (LFNC) |
/Asset/a1036.jpg 39741 Type NMUA - Nonconductive Conduit Liquid-Tight Flexible Non-Metallic Conduit (LFNC) |
|||||
Description |
N/A
Thermoplastic PVC Conduit shall be Anaconda SEALTITE® Type NMUA. Conduit shall be constructed of non-metallic PVC material and shall be used for inside, outside and corrosive applications in accordance with Article 356 of the National Electric Code. Conduit shall be used in applications requiring a temperature range of -17ºF to +176ºF (-27ºC to +80ºC) for dry locations. Conduit shall be UL listed and CSA certified as Type "B" non-metallic conduit. Conduit IP 67 rated when installed with approved end connectors. |
|||||||||
Type | N/A NMUA | |||||||||
Electrical Trade Size | N/A 3/8 in12 mm | N/A 1/2 in16 mm | N/A 3/4 in21 mm | N/A 1 in27 mm | N/A 1-1/4 in35 mm | |||||
Length | N/A 100 ft30.48 m | N/A 100 ft30.48 m | N/A 100 ft30.48 m | N/A 100 ft30.48 m | N/A 50 ft15.24 m | |||||
Packaging | N/A Standard Carton | |||||||||
Inside Diameter | N/A 0.484 to 0.504 in12.294 to 12.802 mm | N/A 0.622 to 0.640 in15.799 to 16.256 mm | N/A 0.820 to 0.840 in20.828 to 21.336 mm | N/A 1.041 to 1.066 in26.441 to 27.076 mm | N/A 1.380 to 1.410 in35.052 to 35.814 mm | |||||
Outside Diameter | N/A 0.690 to 0.710 in17.526 to 18.034 mm | N/A 0.820 to 0.840 in20.828 to 21.336 mm | N/A 1.030 to 1.050 in26.162 to 26.670 mm | N/A 1.290 to 1.315 in32.766 to 33.401 mm | N/A 1.635 to 1.660 in41.529 to 42.164 mm | |||||
Approx. Inside Bend Radius | N/A 2.0 in50.8 mm | N/A 3.5 in88.9 mm | N/A 4.5 in114.3 mm | N/A 6.5 in165.1 mm | N/A 8.0 in203.2 mm | |||||
Approx. Weight per 100 ft | N/A 13 lbs5.90 kg | N/A 14 lbs6.35 kg | N/A 16 lbs7.26 kg | N/A 26 lbs11.79 kg | N/A 34 lbs15.42 kg | |||||
Installation |
N/A
|
|||||||||
Color | N/A GRAY | |||||||||
NEC Articles |
N/A
|
|||||||||
Application |
N/A
General Purpose Non-Metallic-Smooth Inner/Outer Wall Temperature Range: of -17ºF to +176ºF (-27ºC to +80ºC). |
|||||||||
Industry Certifications |
N/A
UL Listed & CSA Certified |
|||||||||
Core Material | N/A Polyvinyl Chloride (PVC) | |||||||||
Ingress Protection (IP) Rating | N/A Ingress Protection (IP) 65/66/67 | |||||||||
Jacket Material | N/A Polyvinyl Chloride (PVC) | |||||||||
Jacket Benefits | N/A Liquid Tight Oil Resistant | |||||||||
|